What was found
SEAT 41C EMERGENCY EXIT SIGN IS HANGING COMPLIED WITH MEL 3351A TERMS CORRECTION SEAT AISLE LIGHT HOUSING IS OPERATIONAL, BUT HOUSING IS BROKEN AND HAS BEEN SECURED. APPROVED MEL 3351A APPLIED MEL COULD NOT LOCATE OVERHEAD BIN EMERGENCY LIGHTING AT SEAT 41C. OUT OF PRECAUTION INSPECTED AND OPS CHECKED NEARBY BIN EMERG LIGHTS, ALL CHECK OK AND ARE INTACT REF AMM 33-51-00, CANNOT LOCATE ANY DEFECTS. NO PLACARD ON FA PANEL, SUSPECT LIGHT POSSIBLY PREVIOUSLY CHANGED. OK TO CONTINUE MEL CLEARED