What was found
STATION 663 BULKHEAD VAPOR BARRIER UPPER ATTACH ANGLE IS CRACKED AT APPROXIMATELY RBL 9.0. SUPPORT TASK NSA EMX N/R 00064. REVIEWED ESFR INFORMATION. REPAIR STA. 663 BULKHEAD VAPOR BARRIER UPPER ATTACH ANGLE AT RBL 9.0 IAW SRM 57-10-10-2R-5 AND ACCOMPLISHED FUEL LEAK CH ECK IAW AMM 28-11-0, LEAK CHECK GOOD, F REPAIRED STA. 663 BULKHEAD VAPOR BARRIER UPPER ATTACH ANGLE AT RBL 9.0 IAW SRM 57-10-10-2R-5 AND ACCOMPLISHED FUEL LEAK CHECK IAW B737-900 AMM 28-11-00, LEAK CHECK GOOD,