Service difficulty report · Oxygen Bottle · Boeing 7879

Difficulty date
May 8, 2025
Submitted
May 12, 2025
Operation
Air carrier
Aircraft
N38955
Make and model
Boeing 7879
Aircraft serial
37814
Aircraft time
46,804 hours, 4,533 cycles
Part
Oxygen Bottle
Part number
4441295115
Part serial
1734
Condition
Leaking
Location
Zone 100
Part time
11,109 hours, 1,172 cycles
Stage of operation
NR
How discovered
O
Nature of condition
O
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CREW OXYGEN LOW ADVISORY CREW OXYGEN PRESSURE IS LOW. POSSIBLE CAUSES ARE; CREW OXYGEN US AGE, LEAKAGE IN TUBING, OR CYLINDER SHUTOFF VALVE IS CLOSED. O2 IN COCKPIT READS 0. INSPECTED CREW O2 BOTTLE, #1 BOTTLE INDICATED ZERO PSI. #2 BOTTLE WAS AT 1500 PSI. OVERBOARD DISCHARGE DISK APPEARS TO REMAIN INTACT. INSPECTED #1 CREW O2 BOTTLE, ALL LINES ARE TIGHT. REMOVED AND REPLACED #1 CREW O2 BOTTLE REF. DMC-B787-A-12-15-08-00B-200A-A. LEAK CHECKED ALL LINES, FOUND NO LEAKS. TESTED O2 IN FLIGHT DECK FROM ALL MASKS, O2 FLOWS FREELY AND DOESNT DROP. ENSURED PSI DIDNT CHANGE FOR 2 HRS. OK FOR CONTINUED USE.

More about the Boeing 787-9