What was found
DUE TO SLIDE DEPLOYMENT, REPLACEMENT OF THE DIAPHRAGM OF THE DOOR DAMPER AND EMERGENCY OPERATION CYLINDER REQUIRED R&R DOOR R2 DIAPHRAGM IN THE PERCUSSION MECHANISM OF THE DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PER AMM 52-10-00-610-001-A. CHARGED THE DOOR DAMPER AND EMERGENCY OPERATION CYLINDER TO CORRECT PRESSURE PER AMM 52-10-00-614-001-A. LEAK CHECK GOOD. PERFORMED RII RESPONSIBILITY AND CRITICAL STEPS OF DOOR R2 DIAPHRAGM PER GMM 09-25-05 SLIDE OPERATING MECHANISMS AND AMM 52-10-00-610-001-A.