What was found
FUEL IMBALANCE AT CRUISE, LOCKING UNLOCKING NO ACTIVE FAULT MSG OR FAULT HISTORY. CONFIRMED NO FUEL LEAK FROM AIRCRAFT, FUEL IMBALANCE FIM TASK 28-22 TASK 847 CARRIED OUT. CONFIRMED THE CENTER FUEL TANK OVERRIDE/JETTISON PUMP DOES NOT TRANSFER BETWEEN LEFT MAIN AND LEFT CENTER TANKS. FURTHER T/S REQUIRED AS PER FIM TASK 28-22 TASK 849. REQUEST MEL 2822R. LEFT CTR L OVRD FUEL PUMP CTRL PULLED AND COLLARED. PLACARD APPLIED FIM 28-22 TASK 849 ACTIONED UP TO AND INCLUDING D 1 (F), LEFT AND RIGHT FUEL TANK QUANTITIES REMAINED CONSTANT FOR OVER 45 MINS. CENTRE TANK QUANTITY ALSO REMAINED CONSTANT. UNABLE TO CARRY OUT FIM 28-22 TASK 849 STEP D (1) (G) AT THIS TIME DUE FUEL TRUCK AVAILABILITY FUEL SCAVENGE SYSTEM FUNCTIONAL TEST CARRIED OUT REF AMM 28-22-00-720-805, LEFT TRANSFER TIME 20 MINS, RIGHT TRANSFER TIME 19 MINS. BOTH WITHIN LIMITS. REF FIM 28-22 TASK 849 STEP D (1) (G), REFUEL/JETTISON AND FUEL FEED MANIFOLD LEAK TEST CARRIED OUT REF AMM 28-21-00-790-802, BOTH TESTS E (1) AND (2) RESULT IN 0 LITRE LEAKAGE AT TECH SERVICES REQUEST, CENTER TANK FUEL PUMP FLOW RATES COMPARED WHEN OPERATING INDIVIDUALLY. BOTH LEFT AND RIGHT CENTER PUMPS TRANSFERRED 8000 LBS OF FUEL IN 7 MINS 0 SECONDS. MEL 2822R REJECTING, CENTER PUMPS FUNCTIONING PER UPDATE REF AMM 28-22-08-720-801, ALL 4 MAIN TANK BOOST PUMP, JETTISON PUMP AND OVERRIDE/JETTISON PUMP DISCHARGE CHECK VALVES FUNCTION CHECK. NIL FUEL TRANSFER ON ANY EICAS FUEL IMBALANCE MESSAGE WAS NOT TRIGGERED IN PRESENT LEG FAULTS