What was found
PSEU HAS A NO DISPATCH FAULT AND MUST BE FIXED REF LP 6541528 LOCKED FOR FIX PERFORMED BITE CHECK OF PSEU, NO EXISTING FAULTS PRESENT. HOWEVE R, LEG 1 SHOWED MM 52-76015 FWD ENTR WARN FLT. T/S MM FAULT PER FIM 52-10 TASK 802, FROM STEP A- UPTO AND INCLUDING E (2) (E). CANNOT DUPLICATE FAULT. PERFORMED FORWARD ENTRY DOOR ADJUSTMENT CHECK PER AMM 52-11-00-820-801, STEP J (SKIN CLEARANCE CHECK). FOUND CLEARANCE CHECK PER TABLE 501, AND FIGURE 503 FAILING AT CORNER A, AND THE LOWER HALF OF D (REF. FIG 503 OF MANUAL). ATTACHED FIG FOR REF PER FIM 52-10- TASK 802, STEP E (2) (4) L1 DOOR WILL REQUIRE RIGGING. PAGE UNLOCKED WHILE PERFORMING INSPECTION OF L FWD ENTRY DOOR, FOUND INDICATION SENSOR OUT OF ADJUSTMENT. SEE FIGURE ATTATCHED TO LOG PAGE. PERFORMED ENTRY SERVICE DOOR INDICATION SENSOR ADJUSTMENT IAW AMM 52-71-11-820-801. INDICATION SENSOR OPS CHECK GOOD. NO FURTHER DEFECTS FOUND AT THIS TIME.