Service difficulty report · Sensor · Boeing 737924ER

Difficulty date
October 26, 2025
Submitted
October 29, 2025
Operation
Air carrier
Aircraft
N68817
Make and model
Boeing 737924ER
Aircraft serial
42747
Aircraft time
36,638 hours, 13,355 cycles
Part
Sensor
Part number
1296663
Part serial
9019
Condition
Faulted
Location
Lt Engine
Part time
111,189 hours, 44,009 cycles
Stage of operation
CR
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CHIME ALERTED LEFT ENGINE BLEED TEMP NEARING BLEED TRIP OFF, DURING CRUISE AND DESCENT. THE BLEED REPORT CAPTURED THAT THE PRE-COOLER OUTLET TEMPERATURE REACHED AS HIGH AS 490 °F, RESULTING IN A LOW BLEED DUCT PRESSURE OUTPUT OF 17 PSI. (SYSTEM HAS GONE INTO OVERTEMP PROTECTION MODE) PERFORMED TEST ON LT PRE-COOLER CONTROL VALVE IAW AMM 36-12-00-700-801. CHECK PASSED. REMOVED AND REPLACED 390 SENSOR IAW AMM 36-13-03. LEAK CHECK PASSED.