What was found
COMPRESSOR STALL AT 2500 FT, ENG 2. ENG SHUTDOWN. NORMAL LANDING, PERFORMED INLET AND EXHAUST VISUAL INSP REF FIM 71-05 TASK 804.NO FOD OR DEFECTS NOTED. PERFORMED EEC BITE CHK REF MM 73-00 TASK 803. NO FAULTS FOUND. PERFORMED ACTUATORS TEST REF MM 71-00-00-700-807-F00. NO FAULTS FOUND. PERFORMED INLET AND EXHAUST VISUAL INSP REF FIM TASK 71-05 TASK 804. NO FOD OR DEFECTS NOTED. PERFORMED BORESCOPE IAW AMM 72-00-00-200-804-F00. FOUND SEVERE DAMAGE TO HPC STAGE 4 ROTOR. COMPLETED ALL REQUIRED OPS CHECKS PER AMM TASK 71-00-02-400-801-F00 ACP AND VERIFIED INSTALLATION OF ENG 2 AS RII REQUIRED REF AMM 71-00-02-400-801-F00 AND GMM 09-25-05.