What was found
FOUND LARGE CREASE IN SKIN ABOVE TOILET SERVICE PANEL.DAMAGE MEASURES APPROXIMATELY 39" LONG X 5" WIDE LOCATED BETWEEN FUSALAGE BS 848 & 887, AND STRINGERS 21L & 22L. INITIAL DEPTH MEASURES 5 TO 7 MM. PER THE REF SRM 53-00-01-1A-5 FIG. 102 SHEET 6 DAMAGE EXCEEDS ALLOWABLE LIMITS. REQUIRES FURTHER EVALUATION. LOCKED FOR REPAIR FWD DENT BETWEEN STA 847 & 867 MEASURES OUT OF LIMITS DUE TO DEPTH OVER .125" RE SRM 53-00-01 AD1. AFT DENT AT AFT END DENT OVER FRAME OUT OF LIMITS RE SRM 53-00-07. NO DENTS ALLOWED. REPAIR ACCOMPLISHED IAW ESR 1-13191-WI-IR , AND EC/RA 5360-02054.