Service difficulty report · Power Supply · Airbus A319132

Difficulty date
December 8, 2025
Submitted
December 11, 2025
Operation
Air carrier
Aircraft
N874UA
Make and model
Airbus A319132
Aircraft serial
2008
Aircraft time
59,547 hours, 36,231 cycles
Part
Power Supply
Part number
32145410
Condition
No Test
Location
Zone 200
Stage of operation
IN
How discovered
C
Nature of condition
L
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING EMERGENCY LIGHTS TEST, AFT PSU EMERGERCY POWER SUPPLY UNIT SHOWED A FAULT. REMOVED AND REPLACED THE POWER SUPPLY IAW AMM 33-51-38/401, CONFIG 00, TESTED OK.