What was found
EMERGENCY EXIT ROW LIGHT FLICKERING ON/OFF 20F INSP FOUND R/H SIDEWALL WINDOW LIGHT AT RT FWD OVERWING EXIT DOOR FLICKERING, PULLED & SAFETYED WDO LT RIGHT C/B E11 ON P92 PNL IN E&E. IAW GMM 05-30-05 2.P. PERFORMED ATTENDANT CONTROL PANEL (ACP). SOFTWARE LOADING.REFERENCE: TASK 23-42-03-470-801. SOFTWARE PASSED, NO ISSUES. LIGHT FUNCTIONS NORMAL. OPENED CB IN ORIGINAL MEL. LIGHT STARTED TO FLICKER AFTER APPX 1HR, R & R EMEGENCY EXIT WINDOW LIGHT ASSEMBLY 20F OPS CHECK GOOD. IAW AMM 33-21-00-960-802.