What was found
HYD PRESS PRI R EICAS PUMP OFF PER ECL PUMP STILL HAS FAULT REMOVED THE RIGHT ENGINE DRIVEN PUMP, FOUND DAMAGE TO THE SHAFT. IN ACCORDANCE WITH DMC B787-A-29-11-02-00B-520A-A FITTED ENGINE DRIVEN PUMP ON RIGHT ENGINE TO DMC-B787-A-29-11-02-00B-720A-A. COMPLETED ALL STEPS UP TO INSTALLATION TEST ONLY. PARAGRAPH D INSTALLATION TEST NEEDS TO BE COMPLETED. CARRIED OUT INSTALLATION TEST PARAGRAPHS D E AND F, INCLUDING AMM B787-A-29-11-00-46A-950A-A FLUSHING REQUIREMENT. LEAK TEST OK. NO DIFFERENTIAL PRESSURE PROBLEMS. OK FOR SERVICE PARTS ADD, INSTALLATION COMPLETED USING CROW BAR TOOL TO DMC-B787-A-29-11-02-00B-720A-A, VBAND CLAMP REPLACED AND SOLENOID REPLACED WITH REF TO TASK 7644898 PARTS USED: 25-7200-3-0340,QTY :1 78-7921-3-0002,QTY :1 78-2900-3-0041,QTY ADD EMP:V939563, :1 00-0586-3-2622,QTY :1 78-2912-3-0002,QTY :1 78-7311-3-0061,QTY :1 00-0585-3-1586,QTY :1 78-7321-3-0020,QTY :1 00-0606-3-0032,QTY :1 78-2900-3-0042,QTY :1 78-7900-3-0003,QTY :1 78-2900-3-0043,QTY :1 78-2900-3-0038,QTY :1 78-7311-3-0040,QTY :1 00-0584-3-1409,QTY :1 78-7264-3-0014,QTY :1 78-7311-3-0059,QTY :1 78-2900-3-0058,QTY :1 78-2911-9-9002,QTY :1 MFG PN ON - 53065-09 MFG SN ON - 530652733 M&E SN ON - 02733 M&E PN ON - 78-2911-9-9002 MFG SN OFF - 530652085 MFG PN OFF - 53065-09 ROTABLE PARTS CHG:TT # 1376629 SN OFF 2085 PN OFF 78-2911-9-9002 PUMP, HYD ENG D OFF 78-2911-9-9002 2085 ON 78-2911-9-9002 2733