What was found
VERTICAL STAB. LT LOWER T/E SEAL STRAP BELOW ACCESS PANEL 324AL CRACKED. REPLACED LT VERTICAL TEE ANGLE. REMOVED BEAM DAMAGED AND REPLACED WITH A NEW BEAM IAW SRM 51-40-02, & DWG 173N1300.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
VERTICAL STAB. LT LOWER T/E SEAL STRAP BELOW ACCESS PANEL 324AL CRACKED. REPLACED LT VERTICAL TEE ANGLE. REMOVED BEAM DAMAGED AND REPLACED WITH A NEW BEAM IAW SRM 51-40-02, & DWG 173N1300.