What was found
HYDRAULIC ODOR ON LANDING. ACCOMPLISHED FIM 21-00, TASK 830. ODOR DISIPATED AT APPROX 1500 FT, NO ODORS AFTER, EXCEPT FOR ODOR IN WHEEL WELL ON WALKAROUND. INSPECTED PACK INLETS, HYD LEVELS, PRESSURIZED HYD SYSTEMS & NO LEAKS NOTED. NO EVIDENCE OF HYD FLUID INGESTION INTO PACKS. PACK OPS NORMAL WITH NO ODORS NOTED IN ANY AREAS OF EXTERIOR OR INTERIOR OF ACFT AT THIS TIME.