What was found
PUNCTURE FOUND BEHIND SPEED TAPE, RT WING, OTBD T/E FLAP LWR SURFACE, 39 INCH FROM INBD EDGE, 45 INCH FROM T/E, DAMAGE MEASURES 0.551 LENGTH X WIDTH 0.354, DAMAGE IS OUT OF LIMITS IAW SRM 57-53-01-1A-1, TABLE 1, SUBPART G. MAXIMUM ALLOWED 0.25. REPAIR CARRIED OUT IAW ECRA 5750-05547, STEPS 1, & 2, VISUAL INSP CARRIED OUT & NO VISABLE SIGNS OF MOISTURE INGRESS , STEP 3 REQUIRES HFEC LOG FLAGGED FOR INSP IAW GMM 09-10-05 IAW ECRA:5750-05547 PART 1 STEP 3, HFEC INSP ACCOMPLISHED WITHIN 5" OF FLAP DAMAGE WRT 767 NTM PART 6: 51-00-19. NO FAST UPSCALE SIGNALS NOTED, NO CRACKS PRESENT. ECRA 5750-05547 STEP 4 ACTIONED SPEED TAPE APPLIED DIP REQUESTED TO COMPLETE A IMPROVED INTERIM REPAIR OR A PERMANENT REPAIR PER PART 3 WITHIN 5 FLT CYCLES IAW ECRA 5750-05547.