What was found
GENERAL VISUAL INSPECTION PROCEDURE, L1 DOOR SLIDE BUSTLE DAMAGED, CONFIRMED DAMAGE SIZE IS WITHIN 3 INCHES IN DIAMETER, DOES NOT GO INTO THE CORE MATERIAL AND ALL BUSTLE ATTACH POINT ARE SECUED AND NOT DAMAGE. APPLIED 2 LAYERS OF 3 M 398 FR CARGO TAPE. ACCOMPLISHED INTERIM REPAIR PER TYPICAL REPAIR MANUAL ECRA 2560-03395 PART 1A. REINSPECTED DAMAGED AREA; TAPE IS SATISFACTORY, & NO FURTHER DAMAGES NOTED IAW ECRA 2560-03395. OKAY TO CONTINUE.