What was found
HYDRAULIC SYSTEM FLUID POOLING ON RIGHT WING BEHIND FLAP TRACK S HROUD . A SYS QTY 60 PERCENT. HYD RESERVOIR SYS A & B QTY WITHIN LIMITS. PERFORMED FIM TASK 28-10 TASK 808 HYD SYST EXTERNAL LEAKAGE CHECK AND FLUID LEVELS FOUND SYSA AT 87 AND SYS. B AT 93 BOTH WITHIN LIMITS ,SERVICED TO OPERATING LIMITS AS PER AMM 12-12-00-610-801 ONLY AS REFERENCE DE ICING LIQUID FOUND ON FLAP FAIRING NUMBER 2 PREVIOUS EVIDENCE OF DE ICING PROCEDURE LOOK FOR EVIDENCE OF HYD LEAKS NIL LEAK WAS FOUND. FOUND HYD RESERVOIRS WITHIN LIMITS RAN ENG 1 AND ENG 2 DURING FIVE MINUTES NO FOUND ANY EVIDENCE OF HYD LEAKS, PARAMETERS WITHIN LIMITS A/C OK TO CONTINUE.