As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FWD CARGO DOOR CUTOUT LOWER THRESHOLD WEB HAS SEVERAL AREAS OF CORROSION. COMPLIED WITH ESFR REMOVED CORROSION,ORIGINAL MATERIAL THICKNESS .040 REMOVED .018 REMAINING .022 FOUND TO BE OUT OF LIMITS IAW SRM 53-30-15 AND SRM 53-00-53. REMOVED DAMAGED WEB AND INSTALLED NEW WEB AND NUTPLATES. 1145538.3 IAW BAC DWG 143A8330 REV B AND SRM 51-40-02 LOCATED AND DRILLED IAW SRM 51-40-05.