What was found
DAMAGE APPROX 21 INCHES AFT OF FWD AVIONICS DOOR. DENT MEASURES 1"W X 1"L X .030" DEEP. AT FR 16R AND 2 RIVETS UP FROM STGR 36R. DENT IS OUT OF LIMITS, IN RESTRICTED AREA REF. SRM 53-11-11-283-012, FRAME 16 INBETWEEN STRINGER 32 AND 31. DENT IS ON RH FRAME 16 .RH STRINGER INBETWEEN RH STR 31 AND RH STR 32 REF SRM 53-12-11-283-012 FIG 4 DENT TYPE 2 SHEET ONE STEP 3 .ALSO FIG 8 DENT TYPE 2 SHEET 8. DENT IS IN EXCLUDED AREA. STARTED TO REMOVE EXISTING FASTENERS .MANUFACTURED STAINLESS STEEL TO INSTALL BETWEEN FRAME AND SKIN. POSITIONED ONE STAINLESS STEEL IN PLACE.REF SRM 52-11-11-300-041 STEP 2,A. COMPLIED WITH SRM 53-11-11-300-041, PROCEDURE (2)A, 2 STEPS B-F. DRILLED OUT REMAINING EXISTING FASTENERS, CUT OUT DAMAGED SKIN, DEBURRED, AND PRIMED CUTOUT.FABRICATED DOUBLER, PICKED UP COMPLETED