What was found
FA REPORTS SMOKE AND FUMES IN AFT OF ACFT. SUBSIDED WITH QRC UPDATED. PER CHECKLIST, SHUTDOWN RECIRC FANS AND SMOKE & ODOR STOPPED. PERFORMED SMOKE ODOR IN THE CABIN INSP IAW AMM 05-51-26-800-801-C1. RESET BREAKER & PERFORMED OPS CHECK & RT RECIRC FAN GENERATED A BUZZING NOISE & TRIPPED BREAKER. PULLED & SECURED RT RECIRC FAN CONT & CABIN AIR BREAKERS & PLACING ON MEL IN REF WITH 2131B. PER CHECKLIST, SHUTDOWN RECIRC FANS AND SMOKE & ODOR STOPPED. R & R RT RECIRC FAN.