What was found
BRAKE TEMP MONITORING SYS, BRAKE TEMP DISPLAYED. NR 7=1, 8=2, 9=3, 10=4, 11=5, 12=6, 13=7, 14=8, BRAKE TEMPS HIGH. MAX LEVEL 01 ON TAKEOFF. BRAKE TEMP LIGHT ON WHEEL 7 AT TEMP 7 LANDED WHEEL 7 BLOWN. PERFORMED HIGH ENERGY STOP CONDITIONAL INSPECTION IAW TASK 05-51-14-212-094 UP TO AND INCLUDING STEP 3(D)(2)(C)(2)(B). STEP 3 STILL REQUIRES COMPLETION ONCE HYD POWER CAN BE REAPPLIED TO ACFT. PERFORMED THE MLG DRAG BRACE DOWN SENSOR CLEARANCE MEASUREMENTS IAW AMM 32-61-02-822-029. CLEARANCE FOUND WITHIN LIMITS.