What was found
CABIN AIR CPRSR R1 ACRID SMOKE ODOR IN COCKPT AND CABIN CAC DEACTIVATED. SMOKE OR FUMES IN CABIN INSPECTION PERFORMED IAW AMM REF DMC-B787-A-05-51-99-99A-282A-A. FOUND SATIS. DEFERRED. RIGHT AIR CYCLE MACHINE INSTALLED REF AMM 21-52-02-02B-520A. ALL MECHANICAL DUCT CONNECTIONS, V-BAND COUPLING, TIE RODS RECONNECTED AND TORQUED. BONDING JUMPERS INSTALLATION AND CONNECTOR, ELECTRICAL HARNESS ROUTING, OPS CHECK/ LEAK CHKD REMAIN TO BE COMPLETED. FINISHED INSTALLATION OF ACM IAW AMM 21-52-02B-520A , ACP LEAK CHECK & OPS CHECK, NO FAULTS NOTED AT THIS TIME. MEL CONDITION IS REVERSED, RAN R1 CAC FOR 30 MINS REF AMM 21-51-19 PERFORMED OPS CHECK. NO ACRID ODOR OR NO SMELLS NOTED AT THIS TIME.