What was found
INSPECTION FOUND 1 INCH CRACKS IN FLOOR INTERCOSTAL AROUND NUTPLATE HOLES AT BL 0 BETWEEN STA 927 AND 947.5. A NEW INTERCOSTAL WAS FABRICATED AND INSTALLED IAW SRM 53-60-51 AND 51-10-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND 1 INCH CRACKS IN FLOOR INTERCOSTAL AROUND NUTPLATE HOLES AT BL 0 BETWEEN STA 927 AND 947.5. A NEW INTERCOSTAL WAS FABRICATED AND INSTALLED IAW SRM 53-60-51 AND 51-10-2.