What was found
INSPECTION FOUND FLOOR SUPPORT T-ANGLE CORRODED AROUND NUTPLATE HOLES BETWEEN STA 328 AND 344, 12 INCHES LEFT OF CENTERLINE. A PART WAS FABRICATED AND INSTALLED IAW SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND FLOOR SUPPORT T-ANGLE CORRODED AROUND NUTPLATE HOLES BETWEEN STA 328 AND 344, 12 INCHES LEFT OF CENTERLINE. A PART WAS FABRICATED AND INSTALLED IAW SRM 51-40-02.