What was found
INSPECTION FOUND FLOORBEAM CORRODED AROUND NUTPLATE HOLES AT STA 294.5. THE FLOORBEAM TOP T-SECTION WAS REMOVED AND REPLACED IAW SRM 53-10-51.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND FLOORBEAM CORRODED AROUND NUTPLATE HOLES AT STA 294.5. THE FLOORBEAM TOP T-SECTION WAS REMOVED AND REPLACED IAW SRM 53-10-51.