What was found
INSPECTION FOUND FLOOR SUPPORTS CORRODED AT LBL 12 BETWEEN B.S. 312-328 AND BETWEEN B.S. 328-344. REPAIRS WERE FABRICATED AND INSTALLED IAW ECRA 5310-03439.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND FLOOR SUPPORTS CORRODED AT LBL 12 BETWEEN B.S. 312-328 AND BETWEEN B.S. 328-344. REPAIRS WERE FABRICATED AND INSTALLED IAW ECRA 5310-03439.