What was found
INSPECTION FOUND FLOORBEAM CORRODED AT B.S. 328 BETWEEN RBL 12 AND RT SIDE AND BETWEEN RBL 12 AND LT SIDE. THE FLOORBEAM WAS REMOVED AND REPLACED IAW SRM 53-10-51, FIGURE 205.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND FLOORBEAM CORRODED AT B.S. 328 BETWEEN RBL 12 AND RT SIDE AND BETWEEN RBL 12 AND LT SIDE. THE FLOORBEAM WAS REMOVED AND REPLACED IAW SRM 53-10-51, FIGURE 205.