What was found
INSPECTION FOUND A .75 INCH CRACK AT R-1 DOOR LOWER FORWARD CORNER FROM UNDER FORWARD LOWER FITTING TO FASTENER HEAD. CUT FRAME AND SPLICED IN NEW FRAME SECTION IAW DRAWING 69-69940. REINFORCED DOOR LOWER CORNER WITH DOUBLER, FILLER, AND SHIMS. STOP FITTING AND SEAL RETAINER WERE REINSTALLED IAW ECRA 5240-01227.