What was found
THE NR 2 ENGINE A-HYD PUMP LOW PRESSURE LIGHT ILLUMINATED AFTER TAKEOFF. THE NR 1 ENGINE A-HYD PUMP LOW PRESSURE LIGHT ILLUMINATED AND THE EMERGENCY CHECKLIST FOR LOSS OF HYD WAS COMPLETED. THE AIRCRAFT WAS RETURNED AND LANDED WITHOUT INCIDENT. MAINTENANCE FOUND FLUID LEAKING FROM CASE DRAIN OF THE NR 2 ENGINE A-HYD PUMP. THE PUMP WAS REMOVED AND REPLACED IAW MM 29-10-32, PAGE 401. IN ADDITION, THE NR 1 ENGINE DRIVEN HYD PUMP WAS REMOVED AND REPLACED. THE A-HYD SYSTEM WAS SERVICED TO FULL. LEAK AND OPERATIONAL CHECKS WERE GOOD.