What was found
INSPECTION FOUND THREE 2 CRACKS IN LOWER KEEL BEAM SKIN PANEL AT BS 726.75, LBL 6 TO RBL 6. THE CRACKS WERE STOP DRILLED AND REPAIRED IAW SRM 53-60-12, FIGURE 202 AND ECRA 5330-02861. A DIP WAS ISSUED TO REINSPECT BLIND FASTENERS EVERY 3,000 FLIGHT CYCLES AND ACCOMPLISH A PERMANENT REPAIR NO LATER THAN 12/31/01 OR 20,000 CYCLES, WHICHEVER OCCURS FIRST.