KOSC - DURING C-2 CHECK INSPECTION FOUND: A PIT STA 560 LEFT INNER CORD LOWER SUPPORT ANGLE CRACKED IN RADIUS ABOVE STR 39. REMOVED CRACKED ANGLE AND FABRICATED NEW ANGLE PER SRM 51-10-21. INSTALLED NEW ANGLE PER SRM'S 51-10-02, 51-21-02 AND MM AND SRM 51-30-02. REF M-40 86588 AD NR 86-18-01 AND CORROSION TASK CARD NR C53-110-01 TASK CARD NR 86587.