What was found
DURING ROUTINE CPCP INSPECTION, FOUND AT BS1060, FROM BOTTOM CENTERLINE TO LBL50, PANEL SUPPORT FRAME WITH CORROSION AROUND ANCHOR NUTS AND FASTENERS. REMOVED DAMAGED T-CHORD, FAB NEW PER SRM 51-10-01. FAB REPAIR ANGLES PER SRM 51-40-02. INSTALLED REPAIR ANGLES AND T-CHORD IAW SRM 51-40-04 FIGURE 1. CORROSION TASK CARD NUMBER C53-100-01. NON-ROUTINE TASK CARD NUMBER 25139.