What was found
STRINGER AT STA 1760, STR 44R CORRODED BEYOND LIMITS. REPAIRED IAW SRM 51-30-02 AND DWG 65B04143 SHT 5. CORROSION APPROX 8 LONG BY 1 WIDE BY .030 DEEP. FOUND DURING ACCOMPLISHMENT OF C, D CHECK, CPCP WORK CARD ACCOMPLISHMENT. WORK ORDER NUMBER MO280, CORROSION TASK CARD NUMBER.