What was found
FLOORBEAM UPPER CAP IN ZONE 200, STA 1780, WL 199, LBL 23 FOUND 1.5 SQUARE AREA OF CORROSION BEYOND SRM LIMITS. ALSO AT LBL 35 FOUND 1.5 X 2 AREA OF CORROSION BEYOND SRM LIMITS. REPAIRED IAW CKF-AMD-087 SUPP SHEETS 1-3. FOUND DURING ACCOMPLISHMENT OF C D AND CPCP AT BOEING WICHITA (KIAB). WORK ORDER NUMBER MO280, CORROSION TASK CARD NUMBER C53-210-01-04.