What was found
PRESSURE FLOOR SKIN AT FS 513.00 BETWEEN RBL 3 AND RBL 5 IS CRACKED. REMOVED DAMAGE AND APPLIED A PERMANENT REPAIR AT FS 513.00 BETWEEN RBL 3 AND RBL 5 IAW BOMBARDIER REO 601R-53-41-914.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PRESSURE FLOOR SKIN AT FS 513.00 BETWEEN RBL 3 AND RBL 5 IS CRACKED. REMOVED DAMAGE AND APPLIED A PERMANENT REPAIR AT FS 513.00 BETWEEN RBL 3 AND RBL 5 IAW BOMBARDIER REO 601R-53-41-914.