What was found
AFTER DRAINING FUEL SUMP DURING PRE-FLIGHT INSPECTION, FOUND FUEL SUMP DRAIN LEAKING FUEL. FOUND FUEL SUMP DRAIN ORING DRY ROTTED. REMOVED AND REPLACED O-RING. THIS IS A COMMON PROBLEM, NEW O-RING MATERIAL NEEDED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFTER DRAINING FUEL SUMP DURING PRE-FLIGHT INSPECTION, FOUND FUEL SUMP DRAIN LEAKING FUEL. FOUND FUEL SUMP DRAIN ORING DRY ROTTED. REMOVED AND REPLACED O-RING. THIS IS A COMMON PROBLEM, NEW O-RING MATERIAL NEEDED.