Service difficulty report · Check Valve · Raythn HAWKER800XP

Difficulty date
March 20, 2014
Submitted
March 24, 2014
Operation
Air carrier
Aircraft
N999RZ
Make and model
Raythn HAWKER800XP
Aircraft serial
258361
Aircraft time
9,906 hours, 6,923 cycles
Part
Check Valve
Part number
HTE4853
Condition
Failed
Location
Hydraulic Sys
Part time
9,906 hours, 6,923 cycles
Stage of operation
CL
How discovered
O
Nature of condition
K, B
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AFTER TAKEOFF, CREW REPORTED GREY & WHITE SMOKE WITH HYD ODOR COMING OUT OF COCKPIT PUNKA LOUVERS SHORTLY AFTER SWITCHING FROM APU BLEED AIR TO MAIN BLEED AIR. CHECK LIST FOLLOWED, EMERGENCY DECLARED & UNSCHEDULED LANDING PERFORMED WITHOUT INCIDENT. EVALUATION FOUND HYD FLUID CONTAMINATION IN RT BLEED AIR SYS. RT BLEED AIR NON-RETURN VLV PN HTE4853 & HYD RESERVOIR BLEED AIR CHECK VLV PN HTE4350 WERE BOTH REPLACED. OTHER BLEED AIR COMPONENTS WERE REPLACED & CLEANED AS NECESSARY.