As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING A PHASE B-INSPECTION, OPERATOR REQUESTED, INSPECT THE AFT ELEVATOR TRIM CABLES. UPON INSPECTION FOUND BROKEN WIRES, TOOK CABLE TENSIONS, FOUND TO BE WITHIN LIMITS AND CABLE WAS CENTERED IN PULLEY. THE CABLE WAS REMOVED AND LOOP TEST SHOWED MORE BROKEN WIRES. THE WEAR ON THE CABLE APPEARS TO BE IN THE SAME LOCATION THAT WE FOUND ON THE PREVIOUS SDRS SUBMITTED. THAT BEING 0 TO 2 DEGREES TAB DOWN AND FRAYED AREA CENTERED ON PULLEY. AN SCR HAS BEEN SUBMITTED TO MFG UNDER NR 250168.