As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING A SCHEDULED INSPECTION THE ELEVATOR TRIM CABLE WAS FOUND TO BE FRAYED BEYOND LIMITS. THIS CABLE ASSY IS LOCATED WHERE THE CABLE TRANSITIONS FROM A VERTICAL RUN TO THE HORIZ AT A PULLEY LOCATED IN THE HORIZ STABILIZER. HAVE SEEN NUMEROUS WITH THIS SAME CONDITION. A SERVICE CONDITION REPORT HAS BEEN SENT TO MFG UNDER NR 613657.