What was found
THE ACFT RETURNED TO DEPARTURE, DUE TO VIBRATION FELT IN THE NOSE AREA DURING TAKEOFF. MX FOUND THE LT NOSE GEAR DOOR OPEN ON LANDING. THE DOOR RELEASE HANDLE WAS CLEANED, LUBED, AND CYCLED. FUNCTIONAL CHECK OF THE DOOR CLOSING AND SECURING WAS NORMAL.