What was found
ON 11/09/10 DURING A LIGHTNING STRIKE INSPECTION, A FASTENER HOLE WAS MISDRILLED AT BS 778, STR 16L. REMOVED DAMAGE AND INSTALLED A PERMANENT REPAIR PER ER/A 487276-14. (DL757103074)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ON 11/09/10 DURING A LIGHTNING STRIKE INSPECTION, A FASTENER HOLE WAS MISDRILLED AT BS 778, STR 16L. REMOVED DAMAGE AND INSTALLED A PERMANENT REPAIR PER ER/A 487276-14. (DL757103074)