What was found
DURING "H" CHECK FOUND FLOOR PANEL 231CF HAS CORRODED INSERTS AND A TORN EDGE. REPLACED FLOOR PANEL. WORK ACCOMPLISHED IAW DWG 3D25-37498.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING "H" CHECK FOUND FLOOR PANEL 231CF HAS CORRODED INSERTS AND A TORN EDGE. REPLACED FLOOR PANEL. WORK ACCOMPLISHED IAW DWG 3D25-37498.