What was found
DENT C2, CARGO COMPARTMENT, LT SIDE STA 1320 - INNER FREE FLANGE. REMOVED DAMAGE AREA PER SRM 53-00-07 REPAIR 5. PERFORMED HFEC INSPECTION OF CUTOUT PER SRM 53-00-07 REPAIR 5. NO ITEMS REMOVED OLD DOUBLER AND FASTENERS PERFORMED BHEC INSPECTION PER SRM 53-00-07 REPAIR 5. NO CRACK FOUND STARTED TO FABRICATE NEW DOUBLER REF SRM 53-00-07 DETAIL III COMPLETED FABRICATION OF REPAIR PARTS PER SRM 53-00-07 REPAIR 5. TREATED AND PAINTED DOUBLER PER SRM 53-00-07 REPAIR 5. BEGAN INSTALL OF REPAIR PER SRM 53-00-07 REPAIR 5. FINISHED INSTALLATION OF REPAIR PER SRM 53-00-07 REPAIR 5.