What was found
FIVE DENTS OF FUSELAGE STA 620-640 BETWEEN STR 14L AND 16L AND CREASE ON SHEAR TIE BS 620 ABOVE STR 16L. FOUND TWO DENT OUT OF LIMITS IAW B757 SRM 53-00-01 ALLOWABLE DAMAGE PG 104 FIG 101 DET 3. HFEC INSPECTION IAW NDTM 51-00-19 PT6 NO CRACKS NOTED IN FIVE DENTS. COMPLIED WITH PR/I 498881-14 REV 4, PREPPED AND PAINTED FUSELAGE REPAIR AREA IAW B757 AMM 51-21-10-377-003. ACCOMPLISHED ER/A 498881-14 REV A.