What was found
FWD CARGO FRAME DENTED BS 600 ABOVE S24L, FRAME OUT OF LIMITS DUE TO LOCATION OF DENT. REMOVED DAMAGED SECTION, FABRICATED AND INSTALLED REPAIR SPLICE IAW SRM 53-00-07.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CARGO FRAME DENTED BS 600 ABOVE S24L, FRAME OUT OF LIMITS DUE TO LOCATION OF DENT. REMOVED DAMAGED SECTION, FABRICATED AND INSTALLED REPAIR SPLICE IAW SRM 53-00-07.