What was found
MX DISCOVERED STATIC DISCHARGE AT BS 646. 3 INCHES BELOW STR 21 RT. DRILLED OUT STATIC DISCHARGE AND INSPECTED. NO FAULTS NOTED. INSTALLED BLIND FASTENER IAW SRM 53-00-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MX DISCOVERED STATIC DISCHARGE AT BS 646. 3 INCHES BELOW STR 21 RT. DRILLED OUT STATIC DISCHARGE AND INSPECTED. NO FAULTS NOTED. INSTALLED BLIND FASTENER IAW SRM 53-00-01.