What was found
MX DISCOVERED STATIC DISCHARGE AT BS 540. SEVEN INCHES BELOW STR 24 RT. DRILLED OUT STATIC DISCHARGE AND INSPECTED. NO FAULTS NOTED. INSTALLED BLIND FASTENER IAW SRM 53-00-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MX DISCOVERED STATIC DISCHARGE AT BS 540. SEVEN INCHES BELOW STR 24 RT. DRILLED OUT STATIC DISCHARGE AND INSPECTED. NO FAULTS NOTED. INSTALLED BLIND FASTENER IAW SRM 53-00-01.