What was found
WHILE ACCOMPLISHMENT OF EA 01-499890-03AD ME12 WORK CARD STEP 30, FOUND TENSION BOLT'S SELF AUGMENT WASHER RIDING ON RADIUS OF INTERNAL BATHTUB FITTING. INSTALLATION OF NEW REPLACEMENT LONGERON FITTING TENSION BOLTS CARRIED OUT IAW PRI 509717-14, REV 1, REF NRC'S AND CARDS : 100-037, 100-245 AND EA 01-499898-03AD OPN NR 1201.