As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
PRIOR TO TOP OF DECENT, CABIN EMERGENCY LIGHT ILLUMINATED. LIGHT BEGAN FLICKERING FOLLOWED BY SMOKE COMING FROM FROM THAT AREA. DIVERTED, MX FOUND CEILING PANELS FULL OF WATER . WATER SEPERATOR DRAIN LINES CLEAR. DRIED OVERHEAD AREA AND LIGHT ASSEMBLIES. REPLACED COELESCER BAGS. RAN PACKS , CYLCLED ALL LIGHTS. ALL OPS CHECK NORMAL. INSPECTED LIGHT ASSEMBLIES . NO SIGNS OF BURNING OR ARCING. ACFT OK FOR SERVICE.