What was found
DURING INSP, FOUND AFT CARGO BAY BS 727I + 5" LBL 8, FLOORBEAM HAS CORROSION. MX FABRICATED CHANNEL SPLICE IAW ERA 492969-14MA SH 2, STEP 1, 3. APPLIED ALODINE & PRIMER IAW SRM 53-00-53, REPAIR 2. INSTALLED CHANNEL SPLICE IAW ERA 492969-14MA.